Passat (B5) – Show hidden menu Climatronic

VAG Coding VCDS ODBeleven VW Passat B5 3B

Purpose : to display the Climatronic’s hidden menu.

Displaying instantaneous digital speed? it’s possible! No need to use your VCDS VAG-COM cable for this tutorial.

Proceed :


With the ignition on and the engine at idle, press the low fan, cool and Eco buttons simultaneously, or the recirculation and eco buttons simultaneously
Immediately on the right-hand side of the climate control display, “diag” (Diagnosis) appears and the options are displayed.

The cold (blue) and hot (red!) buttons are used to navigate through the various menus.

For your information, menu 16 shows the vehicle’s actual speed.

Example: The speed indicated on my speedometer (analog) seems optimistic, at 140 kmh, but the air conditioning,
indicates 134 kmh.

This marked difference is a deliberate choice on the part of the manufacturers.

Other functions provide information on :

– Engine speed
– Engine temperature
– Temperature of all sensors
– On-board computer software version
– Turbo pressure (?)

Depending on the model, you’ll find 45, 65, 72 or 99 menus available (depending on
software version, computer or car model).

These are the codes from the old version. To display, press the recycling button and, while holding this button, press the “up arrow” button, “1c” will appear, move up and down with the + or – temperature buttons. To remove, press “auto”.

Channel Designation
1 – System error
2 – Virtual sensor value
3 – Inside console sensor value
4 – Outside temperature value – water tank sensor
5 – Outside temperature value – bumper sensor
6 – Lower supply sensor value
7 – Front air sensor value
8 – Display check
9 – Digital value of temperature valve return potentiometer
10 – Digital temperature damper setpoint
11 – Digital value of air-conditioning valve return potentiometer
12 – Digital air conditioning valve setpoint
13 – Digital value of foot valve/defrost return potentiometer
14 – Digital foot valve/defrost setpoint
15 – Digital value of supply air damper return potentiometer
16 – Digital supply air damper setpoint
17 – Speed in km/h
18 – Ventilation voltage value (Volts)
19 – Fan voltage setpoint (Volts)
20 – Compressor voltage value (Volts)
21 – Number of very low voltage events (non-volatile)
22 – High pressure switch status
23 – Number of high-pressure events (volatile)
24 – Number of high-pressure events (non-volatile)
25 – A/D value Kick-Down switch
26 – A/D value hot indicator light
27 – Engine speed
28 – Compressor speed
29 – Coding
30 – Software version
31 – Software index
32 – Error counter potentiometer temperature valve
33 – Error meter potentiometer air conditioning valve
34 – Error counter potentiometer foot valve/defrost
35 – Error meter potentiometer supply air valve
36 – Cold stop temperature valve
37 – Hot stop temperature valve
38 – Air conditioning valve stop closed
39 – Air conditioning valve stop open
40 – Foot valve/defrost stop
41 – Foot valve/defrost stop
42 – Supply air damper stop open
43 – Supply air damper stop closed
44 – Rolling cycle counter
45 – Calculated inside temperature (Ninc)
46 – Filtered outdoor temperature (°C)
47 – Unfiltered outdoor temperature (°C)
48 – ECOR
49 – Coolant temperature
50 – Stopping time in minutes
51 – Motor temperature in °C
52 – Compressor stop conditions
53 – Display active electrical outputs: compressor, room air valve, water valve
54 – Control indication number
55 – Outdoor temperature in °C
56 – Virtual indoor sensor °C
57 – Inside console sensor °C
58 – Water tank temperature °C
59 – Bumper temperature °C
60 – Lower supply sensor temperature
61 – Temperature of front air sensor
62 – Solar intensity W/m-1
63 – Filtered solar intensity W/m-1
64 – Delta ventilation increase
65 – Delta transition air conditioning valves
66 – Time cadence /1.6 sec
67 – Cold start correction
68 – Maximum setpoint for P and I components
69 – Foot blow sensor value (cnts)
70 – Foot discharge sensor setpoint (cnts)
71 – Difference (Epsilon)
72 – Part (+ heat / – cool)