Purpose: to activate the locking and unlocking of the central locking system with the KESSY keyless entry system, when moving away from the vehicle.
SFD: yes
Warning! There are 6 lines of coding to do here.
Proceed :
1 – Engine off, ignition off, connect your official VAG-COM VCDS cable to the computer, then plug the other end into your vehicle’s diagnostic socket or OBDeleven box.
2 – Switch on the ignition and run the VCDS program or the OBDeleven application.
Line 1:
3 – Click on“Select”, then click on“09 – Cent. Elect.”.
4 – Unlock SFD protection.
5 – Click on“Adaptation – 10”.
6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose“Automatische_Funktionen – Automatisches_Verriegeln_aktiv“.
7 – On the same page, there’s a second drop-down menu at the bottom
of the page.
Select“Active” and confirm.
Line 2:
3 – Click on“Select”, then click on“09 – Cent. Elect.”.
4 – Unlock SFD protection.
5 – Click on“Adaptation – 10”.
6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose“DevCod_IDGeber_Suche – Unterdrueckung_zyklischer _Suchen_bei_entriegeltem_Fahrzeug_aktiv“.
7 – On the same page, there’s a second drop-down menu at the bottom
of the page.
Select“Active” and confirm.
Line 3:
3 – Click on“Select”, then click on“09 – Cent. Elect.”.
4 – Unlock SFD protection.
5 – Click on“Adaptation – 10”.
6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose“DevCod_Nutzerkonfigurationen – HMIMenue_Aktivierung_Nah_Mittel_Fern_aktiv“.
7 – On the same page, there’s a second drop-down menu at the bottom
of the page.
Select“Active” and confirm.
Line 4:
3 – Click on“Select”, then click on“B7 – Access Startsystem Interface”.
4 – Click on“Security Access – 16” then enter the code“10587”.
5 – Click on“Adaptation – 10”.
6 – On this page, at the top, there is a drop-down menu.
In this drop-down menu, choose“Passive_Komfort – Passive_Komfort_Oeffnen_aktiv”.
7 – On the same page, there’s a second drop-down menu at the bottom
of the page.
Select“Active” and confirm.
Line 5:
3 – Click on“Select”, then click on“B7 – Access Startsystem Interface”.
4 – Click on“Security Access – 16” then enter the code“10587”.
5 – Click on“Adaptation – 10”.
6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose“Passive_Komfort – Passive_Komfort_Togglen_aktiv”.
7 – On the same page, there’s a second drop-down menu at the bottom
of the page.
Select“Active” and confirm.
Line 6:
3 – Click on“Select”, then click on“B7 – Access Startsystem Interface”.
4 – Click on“Security Access – 16” then enter the code“10587”.
5 – Click on“Adaptation – 10”.
6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose“DevCod_AutomatischeFunktionen – Slowpolling_Rechtecksignal_Aktiv“.
7 – On the same page, there’s a second drop-down menu at the bottom
of the page.
Select“Active” and confirm.

Note:
Only possible with software version 0174 or higher.
Not possible with a lower version.
A “High” BCM is also required!
Under ECU identification.
BCM37w_H = OK
BCM37w_M1 = OK
BCM37_M Hardware L = No OK
Does not work if you move away from the tailgate.
The control unit with address B7 is also required!