Golf 7 (5G) – Activate automatic air recirculation

Purpose: in the Discover menu, select whether to activate automatic air-conditioning recycling on start-up. In normal operation, the Climatronic will automatically switch to recycling mode depending on the air quality sensor.

Procedure:
1 – Engine off, ignition off, connect your official VAG-COM VCDS cable to the computer, then plug the other end into your vehicle’s diagnostics socket.

2 – Switch on the ignition and run the VCDS program.

Line 1:

3 – Click on “Select” then click on“08 – Climatronic” /“08 – Auto HVAC”.

4 – Click on “Coding – 07” then click on “Long Coding Helper” .

5 – Select byte 4 then bit 4-5 select: 10 Recirculation Air Setting (stored)