Eos (1F) – Show hidden menu Climatronic

VAG Coding VCDS ODBeleven VW Eos 1F

Purpose: to display the Climatronic’s hidden menu.

Displaying instantaneous digital speed? it’s possible! No need to use your VCDS VAG-COM cable for this tutorial.

Proceed :

It’s really quite simple. Just press the “ECON” button on your air conditioner and the “air extraction up” button, symbolized by a person with an arrow pointing upwards, at the same time.

Then simply move the driver-side climate control knob to access the various temperatures and functions.

What’s it for?

The main things to check are engine temperature, cabin temperature, exterior temperature and digital speed.

For digital speed:

Then set to -19.0 in the left-hand display by turning the left-hand knob, and the right-hand display gives you the “real” speed in km/h.

This is because the “real” speedometer is different from the analogue speedometer (needle) which has passed 60km/h.

Above 99km/h, the right-hand display alternates between the 100km/h in the small right-hand corner and the remaining two digits in the large right-hand corner.

Turning the central knob changes the small exponent number on the left display, which changes the display on the right to a small 2 – the speed is in mph.


List of hidden Climatronic functions


The beginning of each paragraph symbolizes a function (1st line) followed by sub-functions (following lines).

0 System data (temperature setting left)
0 Program number Dig. (temperature setting right)
1 ERL disaster Dig.
2 ERL right Dig.
3 Working point on/on Dig.
4 Automatic ricircolo (motor)/Automatic ricircolo Bit Dig.
5 Heating as stopped I activate Dig.
6 Air quality
7 Derivative Dig.
8 Country code Dig.
9 Zone sensor test °C

1 UIF (temperature setting left)
0 Internal temperature °C (temperature setting right)
1 Surface temperature °C
2 Platinum piastrin temperature (?) °C
3 Platinum piastrin corrector (?) °C
4 uif-Sonnenint (?) Dig.
5 Radiation corrector (?) °C
6 Dynamic correctors °C
7 Ricircolo corrector °C
8 Thermal correctors °C
9 UIF ignition compensation °C

2 Irradiance sensor SX
0 Irradiance not delayed (?) W/m2
1 Irradiance corrector for temperature controller W/m2
2 Irradiance corrector for fan W/m2
3 Value to be digitized.

3 Irradiance sensor DX
0 Irradiance not delayed (?) W/m2
1 Irradiance correction for temperature controller W/m2
2 Irradiance correction for fan W/m2
3 Value to be digitized.

4 Outdoor temperature
0 Outdoor temperature °C
1 Temp. Outdoor CAN line °C
2 Intake air temperature climate °C

5 Theoretical SX temperature
0 Theoretical SX outlet air temp. °C
1 Difference between theoretical and actual temp. °C
2 Value of sx. regulation ½ % /Dig
3 Stell-Max (?) ½ % /Dig
4 Defrost SX

6 Noticed temperature SX
0 Temp. Noticed SX °C
1 Temp. Feet SX °C
2 Temp. Frontal SX °C

7 Theoretical temperature DX
0 Theoretical air temperature DX °C
1 Difference between theoretical and actual temperature DX °C
2 Control values controller ½ % /Dig
3 Stell-Max (?) ½ % /Dig
4 Defrost DX

8 Noticed temperature DX
0 Noticed outlet air temp. DX °C
1 Temp. Feet °C
2 Temp. Frontal °C

9 Theoretical evaporator temperature
0 Theoretical evaporator temperature °C
1 Difference between theoretical and effective evaporator temp. °C
2 Evaporator control values 5mA/Dig
3 Evaporator control modes (see below)

10 Effective evaporator temperature
0 Effective evaporator temperature °C
1 Refrigerant pressure climate bar
2 Average refrigerant temperature climate °C

11 Compressore clim
0 Theoretical electric power but
1 Effective electric power but
2 Max electric power but
3 Kompressor PWM (0… 200) Dig
4 Electric power compressore offset
5 Electric power values
6 Code compressore disinserito

12 Fan climate
0 Theoretical fan voltage V
1 Manual control
2 Fault code
3 Riduction fan V
4 Offset fan (from here to automatic mode) 0.1V

13 Bocchette air temperature SX
0 Theoretical value formattato %
1 Theoretical value actual temp. Bocchette sx. Dig.
2 Conferma el. temp. Bocchette sx. Dig.
3 Limite plus grand temp. Bocchette sx. Dig.
4 Limit min. temp. Bocchette sx. Dig.

14 Bocchette air temperature DX
0 Theoretical value formattato %
1 Theoretical value real temp. Bocchette dx Dig.
2 Conferma el. temp. Bocchette dx Dig.
3 Limite plus grand temp. Bocchette dx. Dig.
4 Limit min. temp. Bocchette dx. Dig.

15 Temperature bocchetta pieds/centrale
0 Theoretical value formattato %
1 Actual theoretical value temp. Bocchetta centrale Dig.
2 Conferma el. temp. bocchetta centrale Dig.
3 Limite plus grand temp. bocchetta centrale Dig.
4 Limite min. temp. bocchetta centrale Dig.

16 Pelle Defrost
0 Theoretical value formattato %
1 Actual theoretical value pelle Defrost Dig.
2 Conferma el. pelle Defrost Dig.
3 Limit plus pelle Defrost Dig.
4 Limit min. pelle Defrost Dig.

17 Pelle ricircolo interne
0 Valeur théorique formattato %
1 Valeur théorique réelle pelle ricircolo Dig.
2 Conferma el. pelle ricircolo Dig.
3 Limite plus grand pelle ricircolo Dig.
4 Limite min. pelle ricircolo Dig.

18 Cold air shovel
0 Theoretical value formattato %
1 Theoretical actual value Cold air shovel Dig.
2 Conferma el. Pelle air froid Dig.
3 Limite plus grand Pelle air froid Dig.
4 Limite min. Cold air shovel Dig.

19 Engine data
0 Speeds’ km/h
1 Engine temperature °C
2 Engine rpm U/min
3 Compressor rpm climate U/min

20 Data sent on CAN
0 of Additional heating (on demand)1 = inserted
1 Conferma el. PTC 1 = inserted
2 Puissance el. effective PTC à 3% air demandé radiatore de
clima%
4 Rappo% de pic de l’air radiatore%
5 Aucune prestation demandée au disp. de chauffage 1=nessuna prestation chauffage

21 Ripartitore d’air Climat
0 Defrost% 1 Frontale%
2 Piedi%
3 Bocchetta areazione%
4 Ricircolo air frais/propre (+ bocchetta… ?) %
5 Évaluation sensore%

22 Timer data
0 Stop period min.
1 Motor running time S
2 Running time with key inserted s

23 Special channel
0 Internal lighting sensor Dig.
1 Air quality sensor

24 Software version
0 Development status
1 Software version
2 Type SW
3 Keep Frozen
4 Version K Matrix
5 EEP -Testflags
6 Codifica Vag (?) 2

25 Canali di prova
0 Canale 0
1 Canale1
2 Canale2
3 Canale3
4 Canale4
5 Canale5
6 Canale6
7 Canale7
8 Canale8
9 Canale9

26 Parameters for readings on crystals
0 I delay s
1 Step/udm (?) digit
2 Limit minimo digit
3 Limit max. digit
4 Step/udm on HellaKit (?) 1=ein

27 Bocchetta areazione directe
0 Theoretical value formattato%
1 Actual theoretical value Bocchetta areazione directe Dig.
2 Conferma el. Bocchetta areazione directe Dig.
3 Limite max. Bocchetta areazione directe Dig.
4 Limite min. Bocchetta areazione directe Dig.

28 Umidita
0 Umidita’22#teorica%
1 Umidita’relative to temperature UIF ? %
2 Temp. WSS crystals °C
3 Temperature of condensation °C
4 Melting point temperature difference °C

29 Raw values himidity
0 Temp. Crystals, corrected °C
1 Temp. Crystals, uncorrected °C
2 Sensor umidità%
3 Sensor temperature °C
4 Condensation point temperature (test measurement) °C
5 Fault code

30 Indicated values you himidity
0 Sensor value termofil oDig.
1 Temperatura rif. termofilo Dig.
2 Periodic duration himidity 10-4 sec
3 Temp. Reference himidity Dig.
4 Himidity Rel. on sensore%
5 Sensor temperature himidity °C
6 Crystal temperature (uncorrected) °C

What’s in it for me?

None, unless you like numbers, and the fact that you can see your speed in real time other than with a needle is very nice.

How do I get out of this menu?

By switching off the engine or pressing the “AUTO” and “ECON” buttons simultaneously.