Goal: Select the outdoor temperature value for icy conditions for which the warning is displayed on the screen. (Ice Warning)

SFD: yes


Proceed :
1 – Engine off, ignition off, connect your official VAG-COM VCDS cable to the computer, then plug the other end into your vehicle’s diagnostic socket or OBDeleven box.

2 – Switch on the ignition and run the VCDS program or the OBDeleven application.

Line 1:

3 – Click on“Select” then click on“5F – Electr. information”.

4 – Unlock SFD protection.

5 – Click on“Adaptation – 10”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose“temperature – dz_ice_warning_entry_temperature” for the value at which the alert sounds to warn of frost. (Origin: 4°C)
Then choose “temperature – dz_ice_warning_exit_temperature“for the frost warning end value (default: 6°C).


7 – On this same page, there is a second drop-down menu at the bottom of the page.
On this menu, choose the temperature value you want.