Q5 (8R) – Deactivate open door alarm using contact

Purpose: to deactivate the alarm which is triggered when the door is opened and the contact is in position P.

Procedure:
1 – Engine off, ignition off, connect your official VAG-COM VCDS cable to the computer, then plug the other end into your vehicle’s diagnostics socket.

2 – Switch on the ignition and run the VCDS program.

Line 1:

3 – Click on “Select”, then click on “46 – Module Confort”.

4 – Click on“Security Access – 16” then enter the code“16017”.

4 – Click on “Adaptation – 10” .

5 – Select Canal 98:

Set value to “0


Line 2:

3 – Click on “Select”, then click on “46 – Module Confort”.

4 – Click on “Coding 07”.

5 – Click on “Long Coding Helper” .

6 – Select Byte 15:

Modify Binary value (save original coding)

Phase 1 with binary:
With initial value: 00000000 (00)
New value: 00000101 (05)

Phase 1 and Facelift:
With initial value: 01000111 (47)
New value: 01001111 (4F)